The weigh-check between weigh-checks

Gauge-Cam Suppression & Day-Tank Audit

It reads the pressure gauges and fuel sight glasses for you, on a schedule, and warns when one is slowly going down.

Readiness Needs edge adapter

The evidence is proven or strong, but this capability still needs a capability-specific ESP32 or Rust runtime adapter.

Evidence Strong theory Supported hypothesis

Published physics or adjacent results support the hypothesis; capability-specific product and site validation are still required.

Runtime family Not mapped

No browser runtime is assigned to this capability yet.

Why live sensing is unavailable

No capability-specific offline runtime is mapped yet. Keep the feature visible, explain the required edge adapter, and never fabricate a live result.

Intended capability

Validate this target only after a capability-specific adapter and ground-truth study exist: Reads clean-agent cylinder pressure gauges and diesel day-tank sight glasses on a schedule: an event camera snapshots each enrolled indicator, on-device vision reads needle angle or meniscus height, and a numeric fill/pressure state is logged per asset — the metal-tank pain the rejected RF gauge could not touch, read from the instrument the vendor already bolted on.

This describes the intended outcome. Readiness is needs edge adapter, evidence is class B, and a catalog mapping or recording is not proof of this outcome at a real site.

Solution blueprint

See the environment before installing it.

This exact kit is one of 191 first-class designs. It includes geometry, objects, nodes, wording, scenarios, installation, limitations, and catalog-bound readiness.

Needs edge adapter

No rendered revision is available yet.

Bundled recording

A related Datacenter scene

This is one recorded vertical scenario. It is not separate validation of every capability in the catalog.

01 The physics

A gauge dial is a purpose-built high-contrast optical indicator: at under 1 m a QVGA frame resolves needle angle to a few degrees, mapping to psi via per-asset enrollment; a sight-glass meniscus is a one-edge detect. Pure optics — no RF penetration claim survives a steel cylinder wall and none is made. Capture is scheduled-event only, from a fixed mount with dedicated local illumination; no streaming path exists.

02 Shared processing path

Scheduled wake -> illuminated bounded capture of enrolled gauge -> on-device needle-angle / meniscus read (TFLite-Micro) -> per-asset calibration map -> fill/pressure log + drift alarm on week-scale slope

This is a capability design path. Components may be shared with other catalog entries; it is not presented as a unique algorithm.

03 Validation plan

Bench across gauge models: read accuracy versus manual gauge reads and weigh checks; lighting and parallax sensitivity from fixed mounts; long-run drift audit against NFPA-scheduled manual inspections.

04 Commercial hypothesis

'The weigh-check between weigh-checks' — for facility fire-protection owners catching slow suppression leaks between NFPA inspections.